Wynik wyszukiwania w bazie Polska Bibliografia Lekarska GBL

Zapytanie: DZIECIĄTKOWSKA
Liczba odnalezionych rekordów: 4



Przejście do opcji zmiany formatu | Wyświetlenie wyników w wersji do druku

1/4

Tytuł oryginału: Comparison of serological specificity of anti-endotoxin sera directed against whole bacterial cells and core oligosaccharide of Escherichia coli J5-tetanus toxoid conjugate.
Autorzy: Łukasiewicz Jolanta, Jachymek Wojciech, Niedziela Tomasz, Malik-Gębicka Małgorzata, Dzieciątkowska Monika, Lugowski Czesław
Źródło: Acta Bioch. Pol. 2002: 49 (3) s.721-734, il., bibliogr. s. 732-734
Sygnatura GBL: 303,116

Hasła klasyfikacyjne GBL:
  • mikrobiologia
  • immunologia

    Typ dokumentu:
  • praca doświadczalna
  • tytuł obcojęzyczny

    Streszczenie angielskie: The rough mutants of Gram-negative bacteria are widely used to induce protective antisera but the nature of the target epitope for such antibodies is not precisely defined. Endotoxin is one of several antigens present on the surface of bacterial cells, which are able to elicit specific antibodies. We studied the specificity of antibodies produced against a conjugate of E. coli J5 endotoxin core oligosaccharide with tetanus toxoid. The use of chemically defined antigen for immunisation excludes the possibility of production of antibodies against otehr cell surface antigens. A comparison of this monospecific anti-endotoxin serum whith antiserum against E. coli J5 whole cells was performed in order to distinguish the role that endotoxin core oligosaccharide plays in the itneraction with humoral host defences form that of other potentially important Gram-negative bacterial surface antigens. The reactivity of both sera with smooth and rough lipopolysaccharides was determined in ELISA, immunoblotting and by flow cytometry. BOth antisera reacted with similar specificity with most lipopolysaccharides of identical or related core type. Less distnct reactions with endotoxins of antibacterial serum in comparison with the anti-conjugate serum were found in all serological tests. LPS of E. coli O100 that showed the strongest reactions with both sera was used to stimulate IL-6, TNFŕ and nitric oxide production by the J-774A.1 cell line. BOth sera were used to inhibit that stimulation and no inhibitroy effects of the examined sera in comparison with non-immune serum were observed.


    2/4

    Tytuł oryginału: Nowa koncepcja estetyki.
    Autorzy: Dzieciątkowska Monika
    Źródło: Mag. Stomatol. 2002: 12 (9) s.16-18, il.
    Sygnatura GBL: 312,932

    Hasła klasyfikacyjne GBL:
  • stomatologia

    Typ dokumentu:
  • praca przeglądowa

    Wskaźnik treści:
  • ludzie


    3/4

    Tytuł oryginału: Skuteczność przetoczeń koncentratów krwinek płytkowych u chorych zimmunizowanych.
    Tytuł angielski: Clinical effectiveness of platelet transfusions in alloimmunized patients.
    Autorzy: Maślanka Krystyna, Apel Daniel, Ceglarek Bernadetta, Uhrynowska Małgorzata, Dzieciątkowska Agnieszka, Żupańska Barbara
    Źródło: Acta Haematol. Pol. 2002: 33 (1) s.75-81, tab., bibliogr. 21 poz., sum.
    Sygnatura GBL: 305,450

    Hasła klasyfikacyjne GBL:
  • onkologia
  • hematologia

    Typ dokumentu:
  • praca kliniczna

    Wskaźnik treści:
  • ludzie
  • dorośli 19-44 r.ż.
  • dorośli 45-64 r.ż.
  • dorośli = 65 r.ż.
  • płeć męska
  • płeć żeńska

    Streszczenie polskie: W pracy oceniono skuteczność 880 transfuzji koncentratów krwinek płytkowych (KKP) przetoczonych trzem grupom osób z małopłytkowością w przebiegu różnych chorób układu krwiotwórczego: a) 47 chorym z przeciwciałami HLA, b) 8 z przeciwciałami HLA i płytkowymi, c) 48 bez wykrywalnych przeciwciał. Przeciwciała HLA były wykrywane w teście limfocytotoksyczności (LCT), a przeciwciała skierowane do płytek w teście immunoenzymatycznym z użyciem przeciwciał monoklonalnych skierowanych do glikoprotein (GP) płytek krwi IIb/IIIa, Ib, Ia/IIa (MAIPA). Skuteczność transfuzji KKP oceniano na podstawie stanu klinicznego chorego l/lub skorygowanego wskaźnika płytek (CCI - corrected count increment). Wykazano, że skuteczność poszczególnych transfuzji u chorych z wykrywalnymi tylko przeciwciałami HLA była podobna jak u osób bez wykrywalnych przeciwciał (brak różnic statystycznych). Natomiast skuteczność KKP u chorych z przeciwciałami HLA i płytkowymi w porównaniu do chorych tylko z przeciwciałami HLA lub bez wykrywalnych była istotnie statystycznie niższa (p 0.01). Ponadto u każdego chorego oceniono brak lub obecność ogólnej oporności na przetaczanie płytki, uznając za oporność ponad 80 proc. nieskutecznych transfuzji. Oporność taką stwierdzono u wszystkich chorych z przeciwciałami HLA i płytkowymi, u 62 proc. chorych tylko z przeciwciałami HLa oraz u 48 chorych bez wykrywalnych przeciwciał.

    Streszczenie angielskie: Clinical effectiveness of 880 platelet transfusions from random donors was evaluated in three groups of hematological patients: a) 47 patients with HLA antibodies, b) 8 patients with HLA and platelet antibodies, c) without detectable antibodies. The HLA antibodies were investigated by the lymphocytotoxicity test (LCT), the platelet antibodies directed to GPIIb/IIIa, Ib, Ia/IIa by the monoclonal antibody immobilization of platelet antigens (MAIPA) technique. The effectiveness of platelet transfusions was assessed taking into account bleeding improvement, corrected count increment (CCI) and both of these parameters. The effectiveness of a particular platelet transfusion in patients with the HLA antibodies alone was similar to that observed in patients without detectable antibodies (the difference was not statistically significant). The effectivenes of platelet transfusions in patients with both, HLA and platelet antibodies, comparing to the patients with HLA antibodies alone or without antibodies, was statistically lower (p 0.01). A general refractoriness to platelet transfusions of each patient ( 80 p.c. noneffective transfusions) was also evaluated. It was observed in all the patients with HLA and platelet antibodies, in 62 p.c. of patients with HLA antibodies alone and in 48 of patients without detectable antibodies.


    4/4

    Tytuł oryginału: Zastosowanie filtrów antyleukocytarnych do izolowania leukocytów z krwi pępowinowej.
    Tytuł angielski: Application of leukoreduction filters for isolation of leukocytes from cord blood.
    Autorzy: Antoniewicz-Papis Jolanta, Lachert Elżbieta, Łętowska Magdalena, Dzieciątkowska Aleksandra, Woźniak Jolanta, Pałynyczko Grażyna, Mariańska Bożena
    Źródło: Acta Haematol. Pol. 2002: 33 (3) s.351-359, il., tab., bibliogr. 32 poz., sum.
    Sygnatura GBL: 305,450

    Hasła klasyfikacyjne GBL:
  • hematologia
  • transplantologia
  • pediatria

    Typ dokumentu:
  • praca doświadczalna

    Wskaźnik treści:
  • ludzie
  • noworodki
  • in vitro

    Streszczenie polskie: Przeszczepianie hematopoetycznych komórek macierzystych (KM) jest metodą leczenia z wyboru wielu chorób rozrostowych układu krwiotwórczego. Źródłem KM może być szpik, komórki z krwi obwodowej lub krew pępowinowa (KP). Długotrwałe przechowywanie materiału do przeszczepienia pochodzącego z krwi pępowinowej wymaga optymalizacji metod zmniejszania objętości pobieranej krwi bez znaczących strat komórek hematopoetycznych z zachowaniem ich wszystkich funkcji życiowych. Preparatyka KP musi być prowadzona w systemie zamkniętym zgodnie z zaleceniami Eurocord Transplant Group. Celem naszej pracy była ocena przydatności filtrów antyleukocytarnych do izolowania leukocytów z krwi pępowinowej z przeznaczeniem do długoterminowego przechowywania. Odzyskano 53,1 p.c. leukocytów, 63,4 proc. komórek jednojądrzastych i 69,1 p.c. komórek CD34+, przy jednoczesnej stracie 97,7 p.c. erytrocytów i 92,7 proc. krwinek płytkowych. Odzyskane komórki były w pełni żywotne i wykazywały po izolacji zdolności klonogenne wynoszące: 69,6 proc. CFU-GM, 70,3 p.c. BFU-E i 64,2 p.c. CFU-mix. Wyizolowane preparaty poddawano mrożeniu w ciekłym azocie, z zastosowaniem 10 p.c. DMSO jako środka krioochronnego. Po kilkutygodniowym przechowywaniu preparaty rozmrażano. Po rozmrożeniu odzyskano 100,8 proc. leukocytów; 118,5 proc. komórek mononuklearnychi 139,6 proc. komórek CD34+. Odzyskanie zdolności klonogennych wyniosło 77,0 p.c. dla CFU-GM, 52,0 p.c. dla CFU-GM, 52,0 proc. dla BFU-E i 71,1 proc. dla CFU-mix. Na podstawie uzyskanych wyników stwierdzono, że filtry antyleukocytarne mogą być stosowane do izolowania leukocytó z krwi pępowinowej przeznaczonej do długotrwałęgo przechowywania.

    Streszczenie angielskie: Hematopoietic stem cell (HSC) transplatnation is an altemative therapy in many hematological diseases. HSC is obtained from bone marrow, peripheral blood stem cells or cord blood (CB). Long-term storage of cord blood transplantation material demands optimalization of method reduction of the volume of collected cord blood with moderate loss of HSC as well as preservation of their viability functions. CB processing should run in a closed system according to Eurocord Transplant Group recommendation. The aim of our study was to estimate the usefulness of leukoreduction filters in isolation of leukocytes from cord blood for long-term storage. The recovery was as follows: leukocytes - 53,1 p.c., mononuclear cells - 63,4 p.c. and CD34+ cells - 69,1 p.c. with 97,7 p.c. erythrocytes loss and 92,7 p.c. platelets loss. Recovered cells were fully viable and their clonogenic capacity was: 69,6 p.c. CFU_GM, 70,3 p.c. BFU-E and 64,2 p.c. CFU-mix. Isolated preparates were frozen in liquid nitrogen with 10 p.c. DMSO as crioprtectant. Preparates were thawed after several week stoarge and the following recovery was obtained: 100,8 p.c. leukocytes, 118,5 p.c. mononuclear cells and 139,6 p.c. CD34+ cells. Recovery clonogenic capacity was 77,0 p.c. for CFU-GM, 52,0 p.c. for BFU-E and 71,1 p.c. for CFU-mix. In conclusion we can state that leukoreduction filters prove useful for isolation of leukocytes from cord blood for long-term storage.

    stosując format: